CONTROL_START
THREAD(mainloop)
ON ONCE (1) DO
dnl 0.425: x/600*255 (60° will result in 255 => maximum fan speed)
double newvalue=0.425*(ONEWIRE_GET(28a4aae002000017));
dnl Set fan to maximum
if (newvalue > 255)
OCR2A = 0;
dnl Disable the fan, cooling makes no sense
else if(newvalue < 120)
OCR2A = 255;
dnl Set the fan to the dynamic value
else
OCR2A = 255-(uint8_t) newvalue;
END
THREAD_END(mainloop)
ON STARTUP DO
dnl PD7 has to be output
DDRD |= 0b10000000;
dnl FastPWM
TCCR2A = (1 << COM2A1) | (1 << COM2A0) | (1 << WGM21) | (1 << WGM20);
dnl Prescaler: 256
TCCR2B = (1 << CS22) | (1 << CS21);
dnl Maximum Speed
OCR2A = 0;
THREAD_START(mainloop)
END
CONTROL_END