Dallas 1-wire Bus: Unterschied zwischen den Versionen
Tron12 (Diskussion | Beiträge) |
Tron12 (Diskussion | Beiträge) (→sh oder bash) |
||
Zeile 105: | Zeile 105: | ||
N_DATE=`echo date | nc -u $NETIOIP $NETIOPORT -q 1 ` | N_DATE=`echo date | nc -u $NETIOIP $NETIOPORT -q 1 ` | ||
− | N_GET_ID=`echo 1w list | nc -u $NETIOIP $NETIOPORT -q 1 | grep - | + | N_GET_ID=`echo 1w list | nc -u $NETIOIP $NETIOPORT -q 1 | grep -qe OK || exit 1` |
echo "Date: $N_DATE" | echo "Date: $N_DATE" | ||
Zeile 112: | Zeile 112: | ||
for i in $N_GET_ID | for i in $N_GET_ID | ||
do | do | ||
− | tmp=`echo 1w convert $i | nc -u $NETIOIP $NETIOPORT -q 1 2>/dev/null | grep - | + | tmp=`echo 1w convert $i | nc -u $NETIOIP $NETIOPORT -q 1 2>/dev/null | grep -qe OK || exit 1` |
tmp=`echo 1w get $i | nc -u $NETIOIP $NETIOPORT -q 1 2>/dev/null ` | tmp=`echo 1w get $i | nc -u $NETIOIP $NETIOPORT -q 1 2>/dev/null ` | ||
echo "Sensor: $i :: $tmp" | echo "Sensor: $i :: $tmp" | ||
done | done | ||
</source> | </source> | ||
+ | |||
==== Perl ==== | ==== Perl ==== | ||
Beispiel in Perl das alle Sensoren ermittelt und anschließend die Werte ausgibt. | Beispiel in Perl das alle Sensoren ermittelt und anschließend die Werte ausgibt. |
Version vom 11. Juni 2010, 07:05 Uhr
Inhaltsverzeichnis
Onewire interface
Ethersex kann 1-wire Temperatursensoren mit ECMD auflisten und abfragen. Es wird eine reine Softwareimplementierung des Protokolls benutzt, was keine weiteren Hardware erfordert, als die Temperatursensoren selbst. Dabei muss beachtet werden, dass der Datapin des Buses in der Standardkonfiguration auf PD6 liegt (kann in der pinning/hardware/netio.m4 oder pinning/hardware/etherrape.m4 geändert werden)
Onewire Hardware
Folgende 1-wire Hardware wird momentan durch Ethersex unterstützt:
- DS1820 (Temperatursensor)
- DS18B20 (Temperatursensor)
- DS1822 (Temperatursensor)
- DS2502 (EEPROM)
- DS2450 (4 Kanal ADC)
Onewire Befehle
unter Linux als erstes netcat starten (hierbei natürlich die IP ggf modifizieren):
netcat 192.168.0.15 2701
danach am prompt:
1w list
Gibt eine Liste mit Hexcodes aller angeschlossenen und erkannten Onewire(tm) Sensoren aus.
1w convert <hexcode>
Veranlasst eine Temperaturmessung des addressierten Sensors, oder wenn das Argument <hexcode> weggelassen wird aller angeschlossener Sensoren.
1w get <hexcode>
Gibt die gemessene Temperatur eines Sensors aus.
Einbindung in die HTTPD-Weboberfläche
Unter httpd/embed/ow.ht.m4, bzw httpd/embed/Xow.ht.m4 liegt eine Weboberflaeche, die alle Sensoren erkennt und ihre aktuelle Temperatur regelmässig per Ajax abfragt und anzeigt. Im Falle von Xow.ht.m4 wird sogar Graph der Temperatur mittels SVG gemalt. Um die Dateien einzubinden, muss man einfach bei aktiviertem Onewiresupport den Webserver und das Datei Inlining aktivieren.
Die Dateien können dann unter ow.ht bzw. unter Xow.ht angezeigt werden.
Anschluss AVR-NET-IO
Für das Pollin AVR-NET-IO Board können die Sensoren DS18S20+ ,
normal Betrieb
parasitären Modus
Pinbelegung:
Einbindung in Control6
Die Sensoren können mit ONEWIRE_GET einfach abgefragt werden. Die Funktion führt automatisch ein convert aus, es sind also keine zwei Schritte erforderlich wie bei dem Zugriff über ECMD. Die Rückgabe erfolgt (analog der Funktion KTY_GET) in Centigrad, also Temperatur * 10. Hier vielleicht ein kleines Beispiel, das die Daten in eine von außen abfragbare Variable übernimmt. Sicher kann man sinnvolleres damit anstellen :-)
CONTROL_START ECMD_GLOBAL(Temperatur, 0); THREAD(read_temp) Temperatur = ONEWIRE_GET(10d85594010800eb); WAIT(10); THREAD_END(read_temp) ON STARTUP DO THREAD_START(read_temp); END CONTROL_END
Beispiele
sh oder bash
Einfaches SH (Linux Shell) Script von stesie (irc) zum Auslesen von einem Wert
#! /bin/sh
SENSORID=10529f7001080016
#ESEXIP=2001:6f8:1209:23:42::17 #IPv6 Adresse
ESEXIP=192.168.255.90
#IPv6
#echo 1w convert $SENSORID | nc6 -u $ESEXIP 2701 -q 1 2>/dev/null | grep -qe OK || exit 1
#echo 1w get $SENSORID | nc6 -u $ESEXIP 2701 -q 1 2>/dev/null | sed -e 's/Temperatur: //'
#IPv4
echo 1w convert $SENSORID | nc -u $ESEXIP 2701 -q 1 2>/dev/null | grep -qe OK || exit 1
echo 1w get $SENSORID | nc -u $ESEXIP 2701 -q 1 2>/dev/null | sed -e 's/Temperatur: //'
bash Script von Tron12 zum Auslesen aller Werte
#! /bin/sh
#
# netcat-openbsd 1.89-3ubuntu2
NETIOIP="-4 192.168.178.249"
#für IPv6:
#NETIOIP="-6 2001:6f8:1209:23:42::17"
NETIOPORT="2702"
N_DATE=`echo date | nc -u $NETIOIP $NETIOPORT -q 1 `
N_GET_ID=`echo 1w list | nc -u $NETIOIP $NETIOPORT -q 1 | grep -qe OK || exit 1`
echo "Date: $N_DATE"
echo "---------------------------------"
for i in $N_GET_ID
do
tmp=`echo 1w convert $i | nc -u $NETIOIP $NETIOPORT -q 1 2>/dev/null | grep -qe OK || exit 1`
tmp=`echo 1w get $i | nc -u $NETIOIP $NETIOPORT -q 1 2>/dev/null `
echo "Sensor: $i :: $tmp"
done
Perl
Beispiel in Perl das alle Sensoren ermittelt und anschließend die Werte ausgibt. Benötigt wird das Modul NET das kein IPv6 kann
#!/usr/bin/perl -w
#Auslesen der 1 Wire Sensoren an einem AVR-NET-IO mit ethersex
use strict;
use Net::Telnet ();
my $esexip="192.168.255.90";
my $esexport="2701";
my $esex;
my @sensor;
my $sensor;
my $dummy;
my $temp;
$esex = Net::Telnet->new || die "kann Ethersex nicht finden";;
$esex->open(Host => $esexip,
Port => $esexport,
Timeout => 2);
#Alles Sensor-IDs auslesen und dem Array @sensor zuweisen
$esex->print("1w list");
($sensor) = $esex->waitfor(Timeout => 2,
String => "OK");
@sensor=split(/\s+/, $sensor);
print "@sensor","\n"; #Kontrollausgabe
my $zahler=@sensor;
print "Anzahl der Elemente :",$zahler,"\n\n";
#Alles Sensore Temperatur einlesen
$esex->print("1w convert");
$esex->waitfor(Timeout => 2,
String => "OK");
#Sensor ID inklusive Wert ausgeben
foreach (@sensor) {
$esex->print("1w get $_");
($dummy,$temp)=$esex->waitfor(Match =>'/[-]?\d+\.\d+/',
Timeout => 5);
print "Temperatur vom ID ",$_,": ",$temp," C°","\n";
}
Python
#!/usr/bin/python
from socket import *
def connectEP():
s = socket(AF_INET, SOCK_STREAM)
s.settimeout(5)
s.connect(("192.168.5.3", 2701))
return s
def getTemperature():
s.send("1w list\n")
sensors = []
sensors_result = {}
# list aller Sensoren
while 1:
response = s.recv(1024).rstrip("\n")
if not response: break
if response != "OK":
sensors.append(response)
else:
break
# wert konvertieren
for sensor in sensors:
s.send("1w convert " + sensor + "\n")
while 1:
response = s.recv(1024).rstrip("\n")
if response == "OK":
break
# wert auslesen
s.send("1w get " + sensor + "\n")
response = s.recv(1024).rstrip("\n").lstrip()
sensors_result[sensor] = response
return(sensors_result)
s = connectEP()
for sensor, value in getTemperature().iteritems():
print sensor + " " + value
PHP
<html>
<head>
<title>ethersex php example</title>
</head>
<body>
<?php
define(IP, '192.168.10.9'); // deine ethersex ip adresse
define(PORT, 2701); // standart port im image
request("1w convert");
$response = request("1w list");
$explode = explode("\n", $response);
for ($i=0; $i < count($explode)-2; $i++) {
echo "Sensor: " . trim($explode[$i]);
echo " -- Wert: " . request("1w get " . $explode[$i]);
echo "<br>\n";
}
function request($request) {
$rs = fsockopen(IP, PORT);
if (!$rs) {
$response = "Kann Verbindung nicht aufbauen!";
}
else {
$response ="";
$request = "!" . $request . "\r\n";
fputs($rs, $request);
while (!feof($rs)) {
$response .= fgets($rs, 128);
}
fclose($rs);
}
return $response;
}
?>
</body>
Günstiger Einkauf von Temperatursensoren bei k1w1 (Michael)
Vom Michael Schultz (k1w1) hab ich die Info erhalten, das er immer DS1820 auf Lager hat und sie sehr günstig weiterverkaufen kann. Auch Mindermengen. Mail: ethersex [AT] keyb [DOT] de